400A Air insulated plug-in busway
Home - Electric Busways - Air insulated bus duct - 400A Air insulated plug-in busway
Air insulated bus duct
400A Air insulated plug-in busway
Basic parameters
100A, 250A, 400A, 630A, 800A, 1000A - 5000A
Rated Current
AC 380V / 415V / 690V / 1000V
Rated Voltage
50Hz / 60Hz
Frequency
Aluminum Alloy
Material
IP40 / IP42 / IP54
Enclosure Protection Rating
-
Indoor/Outdoor
Description
The Air Insulated electrical busway is an ideal power distribution solution for modern industrial workshops, textile mills, and commercial facilities. Unlike sandwich busway duct types, it utilizes air as a primary dielectric medium between conductors, supported by high-strength flame-retardant insulators.
Key Features:
- Excellent Thermal Convection: The spacious enclosure allows heat to dissipate rapidly via air circulation, making it robust for high-duty cycles.
- Modular Tap-off Points: Specifically designed for flexibility. Users can install tap-off units at pre-set openings along the busway to power machines without de-energizing the main line.
- Non-Hysteresis Design: Available with aluminum alloy housing to eliminate magnetic heating losses, further increasing energy efficiency at high currents.
- Safety First: Equipped with internal fire barriers and high-tracking resistance insulators to prevent phase-to-phase faults.
Video
Parameters
| Rated Current | 100A, 250A, 400A, 630A, 800A, 1000A - 5000A |
| Rated Operational Voltage | AC 380V / 415V / 690V / 1000V |
| Rated Insulation Voltage | AC 1000V |
| Rated Impulse Withstand Voltage | 8kV - 12kV (1.2/50μs) |
| Rated Frequency | 50Hz / 60Hz |
| System Configuration | 3P3W / 3P4W / 3P5W |
| Short-time Withstand Current | 30kA - 100kA (Current-dependent) |
| Rated Peak Withstand Current | 63kA - 220kA |
| Dielectric Strength | 3500V / 1 min |
| Insulation Resistance | ≥20MΩ |
| Conductor Material | T2 High-Purity Copper (≥99.95%)or Aluminum |
| Enclosure Material | Galvanized Steel or High-Strength Aluminum Alloy |
| Insulator Material | Flame-Retardant Polyester or Ceramic |
| Ingress Protection (IP) | IP40 / IP42 / IP54 |
| Finish | Electrostatic Polyester Powder Coating (RAL 7032/7035) |
| Standard Section Length | 2.0m / 3.0m (Customizable) |
| Mounting Orientation | Horizontal or Vertical (Riser) |
| Tap-off Outlet Frequency | Every 0.5m / 1.0m (Optional) |
Application Cases